As AI computing density keeps rising, liquid cooling has evolved from an "alternative option" into a must-have for data centers in the high-density computing era. Pipeline connections serve as the core "vessels" that guarantee stable system operation. As a manufacturer specializing in fluid connection solutions, Letone has taken the lead in completing product layout for the core connection layer in the AIDC liquid cooling track. Following the development path of "solid product foundation, deep technological roots, and boundary-breaking collaboration", the company is steadily transforming from a single-component supplier into a liquid cooling thermal management service provider, delivering reliable liquid cooling fluid connection support for the large-scale deployment of high-density computing power.

Building a Tiered Product Portfolio to Achieve Uninterrupted Connections for AIDC Liquid Cooling Scenarios As the core product developed for AIDC liquid cooling applications, Letone's LT800 series graded liquid cooling hose portfolio forms a complete product lineup ranging from cabinet terminals to secondary main piping networks. Each variant is precisely tailored to connection requirements at different positions, moving away from the one-size-fits-all design approach:
LT800A: Dedicated hose for bridging cold plates and water distributors, engineered for highly reliable connection points closest to server chips; LT800B: Cost-effective mainstream option for medium- and low-pressure liquid cooling loops, suitable for large-scale deployment in cabinet branch circuits; LT800C: Core configuration for main pipelines in high-end negative-pressure scenarios, meeting the requirements for long-term stable operation of trunk networks.

Beyond standard hoses, the company also offers special piping products including two-phase fluorinated fluid transfer hoses, stainless steel braided PTFE hoses and bare PTFE tubes, which cater to special working conditions such as high-purity fluid transfer and corrosive media. Supported by a full range of fittings including UQD quick-disconnect couplings, UQDB blind-mate quick connectors and TC tri-clamp fittings, the portfolio fully addresses diverse connection requirements for in-server loops, cabinet branch circuits and trunk piping networks. It helps customers resolve the pain points arising from fragmented procurement across multiple suppliers.
Solidifying Technical Foundations to Ensure Reliability Beyond Basic Deployment
This suite of liquid cooling connection products for AIDC applications builds on Letone's more than ten years of technical expertise in industrial cooling hoses. Before entering the computing liquid cooling sector, the company already delivered proven cooling hose solutions for wind power. These products have endured harsh operating environments and are qualified for four demanding scenarios: water cooling loops for gearboxes at cold northern wind farms, water-cooled cabinets for converters at coastal and offshore wind farms, high-heat zones inside enclosed nacelle electrical compartments, and high-flow oil cooler circulation loops for large-megawatt units.
To meet the operation and maintenance needs of wind turbine OEMs and wind farms, Letone can customize matching connectors and supply integrated hose assemblies. This simplifies component selection, reduces on-site crimping and assembly work, and effectively cuts the overall lifecycle cost for customers.

These manufacturing processes and quality control systems, refined and iterated repeatedly under extreme operating conditions including frigid temperatures, heavy corrosion, high heat and long-duration circulation, lay a solid foundation for the high reliability of AIDC liquid cooling products, enabling stable and dependable operation beyond simple deployment.
Focused on On-site Needs to Build a Collaborative Service System
Building on mature technologies and products, Letone keeps strengthening its service capabilities for the AIDC track and establishing a collaborative service model integrating technical platforms and operational coordination. The company has set up a dedicated AIDC thermal management project team as the centralized technical hub to coordinate R&D, product iteration and market planning. It supports both the Luohe manufacturing base and Shenzhen operation center, with the two locations working in tandem to respond to liquid cooling project demands, rapidly deliver customized solutions and provide one-stop services including technical communication, solution selection and on-site follow-up.
Backed by a comprehensive product portfolio, field-proven technologies validated under stringent working conditions, and the dual-service network linking Luohe and Shenzhen, Letone is steadily advancing its business transformation from a single piping supplier to a liquid cooling thermal management solution provider. Leveraging its core strengths in fluid connection technology, the company continues to expand its liquid cooling business scope, supplying a full set of supporting products such as integrated hose assemblies, PTFE tubing, connectors and sealing rings. It delivers full-lifecycle services covering preliminary design and selection, mid-term product supply and post-implementation operation and maintenance.

Manufacturing enterprises thrive on solid products and reliable services. Letone avoids chasing fleeting trends or superficial gimmicks. It consistently focuses on real pain points within the high-density computing industry. Drawing on decades of expertise accumulated in fluid connection technology, Letone translates its technical strength into proven, trustworthy products and hassle-free supporting services, delivering mature thermal management support for the stable and reliable deployment of high-density computing infrastructure.